Přejít k hlavnímu obsahu
top

Bibliografie

Abstract

DCE-MRI Perfusion Analysis with L1-Norm Spatial Regularization

Bartoš Michal, Šorel Michal, Mangová M., Rajmic P., Standara M., Jiřík Radovan

: Joint Annual Meeting ISMRM-ESMRMB 2018. Book of Absdtracts.

: Joint Annual Meeting ISMRM-ESMRMB 2018, (Paris, FR, 20180616)

: GA16-13830S, GA ČR

: MRI, perfusion analysis, pharmacokinetic modeling, spatial regularization, total variation

(eng): DCE-MRI perfusion analysis suffers from low reliability, especially when 2. generation pharmacokinetic models are used to estimate perfusion parameter maps (voxel-by-voxel estimation) in low SNR conditions. These models provide estimates of plasma flow and capillary permeability in addition to the commonly used parameters Ktrans , k(ap). This contribution presents a method for estimation of perfusion maps using the tissue homogeneity model with incorporated spatial regularization in the form of total variation. The algorithm is based on the proximal minimization methods well established in image reconstruction problems. The use of state-of-the-art minimization and image regularization techniques stabilizes the estimates of perfusion parameter maps and keeps the computational demands low.

: FS

: 20602